Installation Instructions and
Homeowners Manual
20012253 10/09 Rev. 7
Builder Direct Vent
Models:
36CDVXRRN (Rear Vent)
36CDVXTRN (Top Vent)
DO NOT STORE OR USE
GASOLINE OR OTHER
FLAMMABLE VAPORS AND
LIQUIDS IN THE VICINITY OF
THIS OR ANY OTHER
APPLIANCE.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electric switch;
do not use any phone in your
building.
Immediately call your gas
supplier from your neighbors
phone. Follow the gas suppliers
instructions.
If you cannot reach your gas
supplier call the fire department.
WARNING!
IF THE INFORMATION IN THIS
MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING
PROPERTY DAMAGE, PER-
SONAL INJURY OR LOSS OF
LIFE.
PLEASE READ THIS MANUAL
BEFORE INSTALLING AND
USING APPLIANCE
INSTALLER/CONSUMER
SAFETY INFORMATION
FOR YOUR SAFETY
Installation and service must
be performed by a qualified
installer, service agency or
the gas supplier.
D
E
S
I
G
N
C
E
R
T
I
F
I
E
D
C E RT I F I E D

#$62COVER

INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
Page view 0
1 2 3 4 5 6 ... 43 44

Summary of Contents

Page 1 - 36CDVXTRN (Top Vent)

Installation Instructions and Homeowner’s Manual20012253 10/09 Rev. 7Builder Direct Vent Models: 36CDVXRRN (Rear Vent) 36CDVXTRN (Top Vent)DO N

Page 2 - Table of Contents

10CDVX Series Direct Vent Gas Fireplace20012253The fireplace, when installed, must be electrically connected and grounded in accordance with local cod

Page 3

11CDVX Series Direct Vent Gas Fireplace20012253VVVVVVVXXXDEBBBCBMBAJKFLVENT TERMINATION AIR SUPPLY INLETAREA WHERE TERMINAL IS NOT PERMITTEDHIÝi`

Page 4

12CDVX Series Direct Vent Gas Fireplace20012253General Information Assembling Vent PipesCanadian Installations:Venting system must be installed in acc

Page 5

13CDVX Series Direct Vent Gas Fireplace20012253The vent chart should be read in conjunction with the following vent installation instructions to deter

Page 6 - (740 mm)

14CDVX Series Direct Vent Gas Fireplace20012253• Minimum clearances between vent pipe and com-bustible materials are as follows: Top - 1” (25 mm) S

Page 7 - Locating Your Fireplace

15CDVX Series Direct Vent Gas Fireplace20012253FP1005Side View Vent Termination1/25/00 djt22”(559 mm)CLFinished WallSecure with ScrewVent Terminatio

Page 8 - INSTALLHOOD

16CDVX Series Direct Vent Gas Fireplace20012253&0REARFLEXVENTFig. 21 Bend flex pipe up 90° as close to fireplace as pos-sible.FP1604&a

Page 9 - Remote switch

17CDVX Series Direct Vent Gas Fireplace20012253needs to have an immediate rise before going hori-zontal. NOTE: Be careful not to distort the outer fle

Page 10 - General Venting

18CDVX Series Direct Vent Gas Fireplace2001225312341 + 2 + 3 + 4 = 270oCFM132Insert Rear Vent Sidewall2/26/01 staCFM132Fig. 29 Maximum number of elb

Page 11 - US Installations

19CDVX Series Direct Vent Gas Fireplace20012253STEP 6Support the horizontal pipes every 36” (914 mm) with metal pipe straps. Make sure that the horizo

Page 12 - Termination Clearances

2CDVX Series Direct Vent Gas Fireplace20012253PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE.Thank you and congratul

Page 13 - 36CDVXR Venting

20CDVX Series Direct Vent Gas Fireplace20012253Do not back fill around snorkel. A clearance of at least 4” (102 mm) must be maintained between the sno

Page 14 - VO584-100

21CDVX Series Direct Vent Gas Fireplace20012253CFM100 Firestop-Vertical09/20/0011"11"JoistJoistFirestop SpacerNails (4)Upper FloorAttic Insu

Page 15 - (749 mm)

22CDVX Series Direct Vent Gas Fireplace20012253How to Use the Vent GraphThe vent chart should be read in conjunction with the following vent installat

Page 16 - REARFLEXVENT

23CDVX Series Direct Vent Gas Fireplace20012253Since it is very important that the vent-ing system maintain its balance between the combustion air int

Page 17 - 3' (914mm)

24CDVX Series Direct Vent Gas Fireplace200122531234Example: Elbow 1 = 90° Elbow 2 = 45° Elbow 3 = 45° Elbow 4 = 90° Total angular varia

Page 18 - 1 + 2 + 3 + 4 = 270

25CDVX Series Direct Vent Gas Fireplace20012253FP1242Fig. 51 Through the wall.FP1243Fig. 52 Apply high temperature sealant to collars or termina-tio

Page 19 - Foundation Wall

26CDVX Series Direct Vent Gas Fireplace20012253BG402aTop VentBelow grade installation1/26/00 djtFirestop7” Pipe7TDVSNORK (Snorkel)4” (102mm) Clearan

Page 20 - 2/10/99 djt

27CDVX Series Direct Vent Gas Fireplace200122531234Max. 8' (2.4m)FP1245through the roof90 & 45 degree 12/021 + 2 + 3 + 4 = 270°FP1245Fig. 56

Page 21 - 09/20/00

28CDVX Series Direct Vent Gas Fireplace20012253 Venting Components584GVenting ComponentsFirestop spacer2/25/99 djt584HVenting componentsattic insula

Page 22 - 36CDVXT Vertical Venting

29CDVX Series Direct Vent Gas Fireplace20012253Only glass approved by MHSC should be used on this fireplace. The top louvre panel is removed by liftin

Page 23 - A + B = 17' (5.2m) Max

3CDVX Series Direct Vent Gas Fireplace20012253This gas appliance should be installed by a qualified installer, preferably NFI or WETT (Canada) certifi

Page 24

30CDVX Series Direct Vent Gas Fireplace20012253,'#$68LOGSLogsThe 36CDVX logs are shipped in place. If a log is broken, refer to the repla

Page 25 - Below Grade Installations

31CDVX Series Direct Vent Gas Fireplace200122533. Open control access panel.4. Push in gas control knob slightly and turn clock-wise to “OFF”. Do

Page 26

32CDVX Series Direct Vent Gas Fireplace20012253Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP)A.

Page 27 - Typical ceiling/roof support

33CDVX Series Direct Vent Gas Fireplace20012253WARNING: BEFORE DOING ANY GAS CONTROL SERVICE WORK, REMOVE GLASS FRONT. SYMPTOM POSSIBLE CAUSES

Page 28 - 10/20/99 twist lock

34CDVX Series Direct Vent Gas Fireplace20012253The conversion of this appliance from one gas to another must be carried out by an authorized service p

Page 29 - 7!2.).'

35CDVX Series Direct Vent Gas Fireplace20012253Fig. 74 Nova SIT820 Gas Valve.DEFFC108SITregulatorconversion10/03OFFPILOTOFC107SIT820valve conversion1

Page 30 - #$68LOGS

36CDVX Series Direct Vent Gas Fireplace20012253Burner and Burner CompartmentIt is important to keep the burner and the burner compartment clean. At le

Page 31 - Lighting Instructions

37CDVX Series Direct Vent Gas Fireplace20012253MHSC reserves the right to make changes in design, materials, specifications, prices and discontinue co

Page 32 - UVHB26 GAS SUPPLY

38CDVX Series Direct Vent Gas Fireplace20012253CDVX (continued) 15. Flexible Gas Line w/ON/Off Shut-Off Valve 20002500 16. Fan Assy (FK12 Optio

Page 33 - SIT NOVA 820 MILLIVOLT VALVE

39CDVX Series Direct Vent Gas Fireplace20012253FK12This auxiliary fan system increases the efficiency of the circulation of the heating air. The FK12

Page 34 - DJT

4CDVX Series Direct Vent Gas Fireplace20012253Requirements for the Commonwealth of MassachusettsAll gas fitting and installation of this heater shall

Page 35 - FC107/108

40CDVX Series Direct Vent Gas Fireplace20012253

Page 36 - Maintenance

41CDVX Series Direct Vent Gas Fireplace20012253

Page 37

42CDVX Series Direct Vent Gas Fireplace20012253

Page 38 - CDVX (continued)

43CDVX Series Direct Vent Gas Fireplace20012253Lifetime WarrantyThe following components are warranted for life to the original owner, subject to proo

Page 39 - Optional Trim

Efficiency Ratings Model EnerGuide Ratings Steady State (%) D.O.E. Fireplace Efficiency (%) Fan-OFF Fan-ON (AFUE%) 36CDVXRRN 66.9 76 76

Page 40

5CDVX Series Direct Vent Gas Fireplace2001225376”(187 mm)166”(422 mm)3656M” (921 mm) Minimum Rough Opening WidthMinimumRoughOpeningHeightMinimumRo

Page 41

6CDVX Series Direct Vent Gas Fireplace2001225376” (187 mm)166”(422 mm)3656M” (921 mm) Minimum Rough Opening WidthMinimumRoughOpeningHeightMinimumR

Page 42

7CDVX Series Direct Vent Gas Fireplace20012253Top of Unit to Ceiling ... 36” (914 mm)Front of Unit to Combustibles ...

Page 43 - LIMITED LIFETIME WARRANTY

8CDVX Series Direct Vent Gas Fireplace20012253A hearth is not mandatory but is recommended for aesthetic purposes. We recommend a noncombustible hea

Page 44 - Efficiency Ratings

9CDVX Series Direct Vent Gas Fireplace20012253Gas Specifications Max. Min. Input Input Model Fuel Gas Control BTU/h BTU/h 36CD